Product Details:
|
| Detection Principle: | Metal Oxide Semiconductor MOS | Output Signal: | Three Independent Analog Voltage Outputs |
|---|---|---|---|
| Power Supply Voltage: | DC 5V | Maximum Heating Power Consumption: | 88 MW |
| Preheating Stability Time: | ≥15min | Working Temperature: | -30℃ ~ +50℃ |
| Working Humidity: | 10~90% RH | Module Size: | 20mm × 20mm |
| Highlight: | MiCS-6814 triple gas sensor module,CO NO2 NH3 gas sensor,IAQ monitoring gas sensor |
||
Product Description:
YJJ CJMCU-6814 MiCS-6814 Triple Gas Sensor Module for CO NO2 NH3 IAQ Monitoring
Features:
MEMS metal oxide semiconductor (MOS) gas sensor module with pure analog output and no I2C interface. It has three independent heating sensing units, suitable for qualitative / relative detection of air quality. It cannot be directly used as a high-precision measurement-level instrument. Calibration is required.
Electrical parameters
- Power Supply: **DC 5V (4.9~5.1V)**
- Output: **3 analog voltage signals (CO / NH3 / NO2)**
- Pin definitions (from left to right): `CO`, `NH3`, `NO2`, `GND`, `+5V`
- Preheating time: Recommended **24-hour aging preheating**; stable reading after initial power-on is approximately 30 minutes
- Operating temperature and humidity: **-30℃ ~ +85℃, 5%~95% RH (no condensation)**
- Module size: **17 × 14 × 3.2 mm**, with 2 M3 mounting holes
- Weight: ≈2g
Gas detection & range
Table
| Gas | Measuring Range |
| --- | --- |
| CO Carbon Monoxide | 1 - 1000 ppm |
| NH3 Ammonia | 1 - 500 ppm |
| NO2 Nitrogen Dioxide | 0.05 - 10 ppm |
| C2H5OH Ethanol | 10 - 500 ppm |
| H2 Hydrogen | 1 - 1000 ppm |
| CH4 Methane | > 1000 ppm |
| C3H8 Propane | > 1000 ppm |
| C4H10 Isobutane | > 1000 ppm |
>
Note: The three analog input pins of this module correspond **respectively to CO, NH3, and NO2**; other gases are cross-sensitive and cannot be precisely distinguished individually. They exhibit cross-interference characteristics.
Key features and precautions
1. Principle: The resistance of the gas sensor changes. The higher the gas concentration, the greater the change in the corresponding channel resistance, and the ADC reads the voltage change. **It is only suitable for relative change monitoring. The manufacturer does not guarantee the direct ppm absolute accuracy**, and zero-point calibration and load resistance matching must be performed.
2. Cross-sensitivity: Ethanol, hydrogen, and other gases will simultaneously affect multiple outputs. It is not suitable for precise differentiation in complex mixed gas environments.
3. Load resistance: The conventional scheme requires an external voltage divider resistor (the resistance values of different channels vary greatly. CO, NH3, and NO2 recommend different voltage divider resistors).
4. Application scenarios: Simple indoor air quality monitoring, rough exhaust detection, IoT environment collection; **Not suitable for safety explosion prevention, legal metrology, or toxic gas alarm
Specifications:
| Module power supply voltage | DC4.9V-5.1 V |
| Module size | 16.9mm * 14.1mm * 3.2mm, with two M3 mounting holes |
| Carbon monoxide | CO 1 -- 1000ppm |
| Ethanol | C2H5OH 10-500ppm |
| Hydrogen | H2 1 -- 1000ppm |
![]()