Product Details:
|
| Nominal Range: | 0 - 30 Ppm HCl | Maximum Overload: | 100 Ppm |
|---|---|---|---|
| Sensitivity: | 0.3 ± 0.1 μA/ppm | Resolution: | 1 Ppm |
| T90 Response Time: | ≤ 70 S | Output Linearity: | Linear Output |
| Long-Term Drift: | < 2% Signal / Month | Bias Voltage: | +200 MV |
| Highlight: | Electrochemical HCl Sensor 0-30ppm,HCl Gas Sensor for Leak Monitoring,OEM Electrochemical HCl Sensor |
||
Product Description:
YJJ 4HCL CLE-1431-400 Electrochemical HCl Sensor 0-30ppm for Chemical Leak Monitoring OEM
Features:
HCL CLE-1431-400 Electrochemical Hydrogen Chloride (HCl) Sensor) Type: Electrochemical, 4-Series Classic Line, Detects Hydrogen Chloride HCl
Core Performance Parameters
| Model | CLE-1431-400 (4-HCl) |
| Nominal Range | 0 - 30 ppm HCl |
| Maximum Overload | 100 ppm |
| Sensitivity | 0.3 ± 0.1 μA/ppm |
| Baseline (20℃) | -0.2 ~ 1.0 μA |
| Baseline Drift (-20~50℃) | Equivalent 0 - 5 ppm HCl |
| Resolution | 1 ppm |
| T90 Response Time | ≤ 70 s |
| Output Linearity | Linear Output |
| Long-Term Drift | < 2% Signal / Month |
| Bias Voltage | +200 mV |
Environmental Operating Conditions
- Operating Temperature: **-20 ℃ ~ 50 ℃**
- Operating Humidity: 15% - 90% RH, **No Condensation**
- Pressure: 90 - 110 kPa
- Expected Service Life: 2 years in air
- Warranty: 12 months after shipment
- Sealed Storage Validity: 6 months; Storage Temperature: 0 - 20 ℃
Physical Specifications
- Weight: Approximately 5 g
- Installation: Directionally insensitive
- Important Note: **Do not directly solder the sensor pins, recommend PCB socket connection**
Cross-Interference (Equivalent HCl Reading)
| Interference Gas | Concentration | Equivalent HCl Output |
| --- | --- | --- |
| H2 Hydrogen | 2000 ppm | 0 |
| CO Carbon Monoxide | 100 ppm | 0 |
| NO Nitrogen Oxide | 20 ppm | 50 ppm |
| NO2 Nitrogen Dioxide | 10 ppm | 1 ppm |
| H2S Hydrogen Sulfide | 25 ppm | 130 ppm |
| SO2 Sulfur Dioxide | 20 ppm | 35 ppm |
| N2 Nitrogen | 100% | 0 |
>
Note: The cross-sensitivity may fluctuate by ±30% depending on the batch and lifespan; hydrogen sulfide, sulfur dioxide, and nitrogen monoxide cause significant interference. Use with caution when these gases are present in the working conditions.
Standard test conditions
20 ℃, 50% RH, 100 kPa atmospheric pressure
Specifications:
| Weight | 5g |
| Maximum overrun range: | 0-50ppm |
| Signal output: | 0.1 0.02mA |
| Response time (T90) | < 15s |
| Load resistance | 100 Ω |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255