Product Details:
|
| Nominal Range: | 0 To 30 Ppm | Maximum Overload: | 100 Ppm |
|---|---|---|---|
| Sensitivity: | 0.3 ± 0.1 μA/ppm | Resolution: | 1 Ppm |
| Response Time (T90): | ≤ 70 Seconds | Baseline (at 20°C): | -0.2 To 1.0 μA |
| Highlight: | 4HCL CLE-1431-400 HCl sensor,electrochemical HCl gas sensor,industrial HCl leak detection sensor |
||
4HCL CLE-1431-400 Electrochemical Hydrogen Chloride Sensor for Industrial Safety & Leak Detection Confined Space Entry
High-Precision Electrochemical Sensing: Delivers accurate and repeatable measurements with a sensitivity of 0.3 ± 0.1 μA/ppm and 1 ppm resolution for detecting low HCl concentrations.
Compact & Durable Design: Weighing only about 5 grams, the sensor's housing incorporates a small capillary diffusion barrier that regulates gas access while protecting the internal electrochemical cell. It is designed for PCB socket mounting (soldering is not recommended as it may damage the sensor).
Wide Operating Envelope: Functions reliably across -20°C to +50°C and 15–90% RH (non-condensing), with an operating pressure range of 90–110 kPa.
Long Service Life & Stability: Offers a typical 2-year lifetime in air and a long-term stability of < 2% signal loss per month, reducing replacement frequency and maintenance costs.
Industrial Safety & Leak Detection: Integrated into portable and fixed gas detectors for monitoring HCl in chemical plants, petrochemical facilities, and laboratories where HCl is used, stored, or generated as a byproduct.
Emissions & Process Monitoring: Used in stack monitoring and process control where hydrogen chloride is a critical parameter (e.g., waste incineration, chemical synthesis).
Confined Space Entry: Employed in pre-entry safety checks for tanks, vessels, and other confined spaces where HCl accumulation poses a risk.
| Sensor Type | Electrochemical, 3-electrode |
| Target Gas | Hydrogen Chloride (HCl) |
| Nominal Range | 0 to 30 ppm |
| Maximum Overload | 100 ppm |
| Sensitivity | 0.3 ± 0.1 μA/ppm |
| Resolution | 1 ppm |
| Response Time (T90) | ≤ 70 seconds |
| Baseline (at 20°C) | -0.2 to 1.0 μA |
| Baseline Drift (-20°C to +50°C) | Equivalent to 0 to 5 ppm |
| Long-Term Stability | < 2% signal loss per month |
| Bias Voltage | +200 mV |
| Operating Temperature | -20°C to +50°C |
| Operating Humidity | 15% to 90% RH (non-condensing) |
| Operating Pressure | 90 to 110 kPa |
| Storage Temperature | 0°C to 20°C (in original packaging) |
| Storage Shelf Life | 6 months (in dedicated packaging) |
| Expected Lifetime | 2 years in air |
| Weight | Approx. 5 grams |
Contact Person: Miss. Xu
Tel: 86+13352990255