Product Details:
|
| Target Gas: | Carbon Dioxide (CO2) | Measurement Range (this Variant): | 0-20% CO2 |
|---|---|---|---|
| Readings Per Second: | 2 | Accuracy (typical, 0-20%): | ±(70 Ppm + 5% Of Reading) |
| Time To First Reading: | < 1.2 Seconds | Response Time: | < 30 Seconds |
| Highlight: | NDIR CO2 sensor industrial safety,CO2 sensor incubators healthcare,CO2 sensor food storage aerospace |
||
ExplorIR-M-20 NDIR CO2 Sensors for Industrial Safety Incubators & Healthcare Aerospace & Food Storage
Typical Applications:
Industrial Safety: Fixed gas detectors and area monitors in demanding industrial environments.
Incubators & Healthcare: CO2 measurement in cell incubators and medical equipment, where the sensor's high-humidity tolerance (up to 95% RH) is advantageous.
Transportation & Refrigeration: Cold-chain monitoring and controlled-atmosphere transport containers.
Horticulture & Agriculture: Greenhouse CO2 enrichment monitoring and controlled-environment agriculture.
Aerospace & Food Storage: Applications requiring reliable performance under vibration and environmental stress, including food packaging and food storage/transportation.
| Manufacturer / Series | Gas Sensing Solutions (GSS) / ExplorIR-M |
| Part Number | EXPLORIR-M-20 (formerly MinIR-GC-0026) |
| Sensor Technology | NDIR (Non-Dispersive Infrared), solid-state LED source |
| Target Gas | Carbon Dioxide (CO2) |
| Measurement Range (this variant) | 0–20% CO2 |
| Platform Range Options | 0–5%, 0–20%, 0–60%, 0–100% |
| Accuracy (typical, 0–20%) | ±(70 ppm + 5% of reading) |
| Readings per Second | 2 |
| Time to First Reading | < 1.2 seconds |
| Response Time | < 30 seconds (diffusion limited, GSS flyer); 120 s (distributor listing) |
| Sample Method | Diffusion |
| Measurement Output | UART |
| Supply Voltage | 3.25 V – 5.5 V (3.3 V recommended) |
| Power Consumption (typical) | < 3.5 mW @ 3.3 V |
| Operating Temperature | 0°C to +50°C (standard); −25°C to +55°C (extended) |
| Operating Humidity | 0–95% RH, non-condensing |
| Operating Pressure | 500 mbar to 2 bar (GSS flyer); 500 mbar to 10 bar (distributor listing) |
| Dimensions | ø20.9 mm × 21.7 mm |
| Weight | 4 g (catalog); 8 g (distributor shipping weight) |
| Storage Temperature | −40°C to +70°C |
| Sensor Lifetime | > 15 years |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255