logo
Home ProductsGas Sensor

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry
4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry 4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry 4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry 4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry 4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry 4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry

Large Image :  4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry

Product Details:
Place of Origin: UK
Brand Name: CITY
Model Number: 4HCL CLE-1431-400
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Standard Package
Delivery Time: 1-2Workingdays
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: 3000PCS/Month

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry

Description
Measurement Range: 0–30 Ppm Maximum Overload: 100 Ppm
Sensitivity: 0.3 ±0.1 μA/ppm Resolution: 1 Ppm
Highlight:

Hydrogen Chloride Gas Sensor

,

Three-electrode Electrochemistry Sensor

,

4HCL CLE-1431-400 Gas Sensor

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry


Specification:

T90 response time ≤70 s
Bias voltage +200 mV(must be accounted for in the circuit design)
Baseline (20°C) -0.2 to 1.0 μA
Long-term drift <2% of signal per month
Operating temperature -20°C to +50°C
Humidity 15–90% RH, non-condensing
Pressure 90–110 kPa
Expected lifespan 2 years in air
Warranty 12 months from date of shipment
Weight Approx. 5 g
Storage 6 months in sealed packaging; storage temperature 0–20°C

4HCL CLE-1431-400 Hydrogen Chloride Gas Sensor Three-electrode Electrochemistry