Product Details:
|
| Zero Repeatability: | ±10 Ppm (all Ranges) | Response Time (T90): | < 40 S @ 20 °C Ambient |
|---|---|---|---|
| Maximum Power Requirements: | 5.0 VDC, 60 MA Max. | Minimum Operating Voltage: | 2.0 VDC, 20 MA Max. |
| Source Drive Frequency: | 1.5-3 Hz | Active Output In N2 (peak-to-peak): | 60-100 MV @ 2.1 Hz, 50% Duty Cycle |
| Highlight: | NDIR CO2 sensor HVAC,NDIR CO2 sensor IAQ monitors,NDIR CO2 sensor combustion analyzers |
||
IRC-A1 Non-dispersive Infrared (NDIR) CO2 Sensor for HVAC & Indoor Air Quality (IAQ) Monitors Combustion Analyzers
Typical Applications:
The IRC-A1 is designed for instruments requiring accurate CO2 measurement across diverse concentration regimes:
HVAC & Indoor Air Quality (IAQ) Monitors: Demand-controlled ventilation and indoor air quality assessment in the 0–5,000 ppm range.
Industrial Safety Instruments: Personnel protection and area monitoring where CO2 may reach hazardous levels up to 5% vol.
Combustion Analyzers: Flue gas and combustion efficiency monitoring in the 0-20% vol range.
High CO2 Process Control: Monitoring and control in industrial processes operating at concentrations up to 100% vol.
| Parameter | Specification |
|---|---|
| Manufacturer / Series | A-Series NDIR |
| Part Number | IRC-A1 |
| Sensor Technology | NDIR (Non-Dispersive Infrared), dual-channel pyroelectric detector |
| Target Gas | Carbon Dioxide (CO2) |
| Housing Format | Industry-standard miniature 20 mm diameter gas sensor housing |
| Measurement Ranges | IAQ: 0–5,000 ppm; Safety: 0–5% vol; Combustion: 0–20% vol; Process: 0–100% vol |
| Accuracy (%FS) | IAQ: ±1% FS; Safety: ±1.5% FS; Combustion: ±2.5% FS; Process: ±4% FS |
| Zero Resolution | IAQ/Safety: 1 ppm; Combustion: 2.5 ppm; Process: 4 ppm |
| Full-Scale Resolution | IAQ: 15 ppm; Safety: 100 ppm; Combustion: 500 ppm; Process: 0.5% vol |
| Zero Repeatability | ±10 ppm (all ranges) |
| Full-Scale Repeatability | IAQ: ±50 ppm; Safety: ±500 ppm; Combustion: ±2500 ppm; Process: ±5000 ppm |
| Response Time (T90) | < 40 s @ 20 °C ambient |
| Maximum Power Requirements | 5.0 VDC, 60 mA max. (50% duty cycle source drive) |
| Minimum Operating Voltage | 2.0 VDC, 20 mA max. (50% duty cycle source drive) |
| Source Drive Frequency | 1.5–3 Hz (recommended 2–2.25 Hz) |
| Active Output in N2 (peak-to-peak) | 60–100 mV @ 2.1 Hz, 50% duty cycle |
| Reference Output in N2 (peak-to-peak) | 40–80 mV @ 2.1 Hz, 50% duty cycle |
| Warm-Up Time | To final zero ±100 ppm: < 30 s @ 20 °C; To specification: < 30 minutes @ 20 °C |
| Operating Temperature Range | -20 °C to +50 °C |
| Storage Temperature Range | -40 °C to +75 °C |
| Humidity Range | 0–95% RH, non-condensing |
| Temperature Sensor | Integral NTC thermistor |
| MTBF | > 5 years (NDIR cell) |
| Weight | 15 g |
| Dimensions (approx.) | Width 20 mm; Height 20.7 mm |
| Pin Configuration | 7 pins: Lamp return, Lamp +5V, +5V Pyro supply, Detector output, Reference output, Thermistor output, 0V Pyro supply and case connection |
| Handling Precautions | Use antistatic precautions; do not cut pins; do not solder directly to pins |
Contact Person: Miss. Xu
Tel: 86+13352990255