Product Details:
|
| Measuring Range: | 0.4 - 100 Ppm | Resolution: | 0.1 Ppm |
|---|---|---|---|
| Detection Limit: | 0.4 Ppm | Response Time (t-90): | ≤ 15 Seconds |
| Operating Humidity: | 10 - 90 % RH | Operating Pressure: | 700 - 1300 HPa |
| Highlight: | H2S single gas detector,continuous hydrogen sulfide monitor,Pac 6500 environmental air analyzer |
||
Pac 6500 H2S Single Gas Detector for Continuous Monitoring of Hydrogen Sulfide (H2S) in Environmental Air
The Pac 6500 (H2S) is a personal safety device for workers who may be exposed to hydrogen sulfide in their immediate breathing zone. Its application profile is defined by the need for continuous, wearable protection rather than pre-entry screening.
Oil & Gas Operations: Upstream drilling, well servicing, and refinery units where H2S is a naturally occurring or process-generated hazard.
Wastewater & Confined Space Work: Sewer systems, lift stations, and treatment plants where anaerobic decomposition produces H2S; worn by personnel during inspection and maintenance activities.
Chemical & Petrochemical Plants: Process areas, loading racks, and maintenance turnarounds where H2S may be released.
Emergency Response: Hazardous-materials and rescue scenarios requiring rapid, wearable detection for responder safety.
| Device Type | Personal single-gas detector (non-disposable) |
| Target Gas | Hydrogen Sulfide (H2S) |
| Sensor | DrägerSensor XXS H2S LC (electrochemical) |
| Measuring Range | 0.4 - 100 ppm (sensor capability up to 200 ppm) |
| Resolution | 0.1 ppm |
| Detection Limit | 0.4 ppm |
| Response Time (t-90) | ≤ 15 seconds |
| Default Alarm Thresholds (A1 / A2) | 5 ppm / 10 ppm (factory-set; user-adjustable) |
| Alarm Type | 360° triple alarm: visual (flashing LEDs, top & bottom), acoustic (90 dB), vibration |
| Operating Temperature (H2S) | −40 °C to +50 °C (sensor-dependent; general device range −40 to +55 °C) |
| Operating Humidity | 10 – 90 % RH |
| Operating Pressure | 700 – 1,300 hPa (mbar) |
| Housing Protection | IP68 (dust-tight, water-immersion rated) |
| Dimensions (W × H × D) | 64 × 84 × 20 mm (some listings cite 60 × 84 × 20 mm) |
| Weight | Approx. 106 g (113 g with clip) |
| Battery / Sensor Service Life | 2 years maintenance-free (H2S version; battery and sensor not replaced during this period) |
| Battery Type | Replaceable lithium battery (accessible after service life) |
| Data Logging | Concentration + event logger with date/time stamp; PC interface |
| Readiness Indicator | D-Light (confirms passed function test and readiness) |
Contact Person: Miss. Xu