Product Details:
|
| Gas Detected: | Ethylene (C2H4) | Measurement Range: | 0 To 1% VOL |
|---|---|---|---|
| Output Interfaces: | Analog + Digital | Operating Voltage: | 3.0-6.0 VDC (nominal 5.0 VDC) |
| Response Time (T90): | < 30 Seconds | Operating Temperature: | -40 °C To +70 °C |
| Highlight: | C2H4 ethylene gas sensor,micro infrared gas sensor,0-1%VOL gas sensor |
||
IRS4 C2H4 Ethylene (0-1%VOL) Intelligent Micro Infrared Gas Sensor for Environmental Monitoring Medical & Biological Engineering
Features:
NDIR Detection Principle: Measures ethylene via infrared absorption, a method that is inherently immune to sensor poisoning and requires no oxygen for operation—unlike catalytic or electrochemical alternatives.
0–1%VOL Measurement Range: Configured for 0 to 1% volume ethylene detection, suitable for applications requiring mid-range concentration monitoring rather than trace-level (ppm) measurement.
Dual Output Interfaces: Provides both analog and digital signal outputs, with the sensor directly outputting a linearized, temperature-compensated gas concentration value for ease of integration.
Wide Operating Temperature: Rated for operation from −40 °C to +70 °C, supporting deployment in demanding environmental conditions.
Fast Response: T90 response time is less than 30 seconds.
Long-Term Stability: Long-term zero drift is specified at < ±1% F.S. per month (under powered conditions).
Compact Intelligent Design: As a “smart” micro sensor, it integrates signal processing and temperature compensation internally, reducing the burden on the host instrument’s electronics.
Environmental Monitoring: Ethylene is a plant hormone and an indicator of combustion; NDIR sensing is applicable to ambient air quality and emission monitoring.
Agricultural & Horticultural Control: Ethylene monitoring in cold-chain transport, controlled-atmosphere storage, mushroom cultivation, and greenhouse environments where ethylene affects ripening and product quality.
Biogas & Process Gas Analysis: Ethylene is a constituent of biogas and certain process streams; the 0–1%VOL range supports mid-concentration measurement in these applications.
Industrial Safety & Chemical Processing: Detection of ethylene in petrochemical, chemical, and oil & gas facilities where flammable or process concentrations may be present.
Medical & Biological Engineering: The NDIR platform’s stability and lack of consumables make it suitable for certain medical or bioprocess monitoring contexts.
| Sensor Series | IRS4 |
| Gas Detected | Ethylene (C2H4) |
| Measurement Range | 0 to 1% VOL |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Oxygen Dependency | None |
| Poisoning Susceptibility | Immune to catalytic sensor poisoning |
| Output Interfaces | Analog + Digital |
| Output Signal | Linearized, temperature-compensated concentration value |
| Operating Voltage | 3.0–6.0 VDC (nominal 5.0 VDC) |
| Average Operating Current | ≈ 60 mA @ 5.0 VDC |
| Response Time (T90) | < 30 seconds |
| Operating Temperature | -40 °C to +70 °C |
| Storage Temperature | -40 °C to +85 °C |
| Long-Term Zero Drift | < ±1% F.S. / month (powered) |
Contact Person: Miss. Xu
Tel: 86+13352990255