Product Details:
|
| Minimum Detection Limit: | 100 Ppb | T90 Response Time: | < 3 Seconds |
|---|---|---|---|
| Sensitivity: | > 0.65 MV/ppm @ 100 Ppm | Lamp Energy: | 10.6 EV |
| Supply Voltage (internal Regulator): | 3.6 - 18 V | Current: | 20 -32 MA |
| Highlight: | MiniPID2 PID gas sensor,OEM photoionisation detector sensor,PPM gas sensor OEM |
||
MiniPID2 Photoionisation Detector (PID) Gas Sensor for MiniPID2 PPM Is an OEM Photoionisation Detector (PID) Gas Sensor
Widest dynamic range in its class – 0 to >4000 ppm, covering both trace and elevated VOC concentrations.
Lamp-out diagnostic – The only PID sensor on the market that can flag lamp failure.
Humidity resistance – Patent Fence Electrode Technology minimises humidity interference, a common source of false readings in PID sensors.
Anti-contamination design – Protects the sensing electrode stack and extends service life in demanding environments.
Exceptional lamp life – 10,000 hours of continuous operation from the 10.6 eV lamp.
Easy serviceability – The electrode stack and lamp are removable and pneumatically sealed, allowing straightforward maintenance.
Fast response – T90 response time of <3 seconds, with rapid clear-down.
Proven longevity – Expected operating life >5 years; manufactured in the UK.
Series 4 / A footprint – Standardised mechanical format for drop-in integration.
The MiniPID 2 PPM sensor is used in OEM gas detection instruments and integrated systems for:
Environmental source monitoring and ambient air / stack monitoring
Fence-line monitoring (indoor and outdoor)
Fugitive emissions detection and LDAR (Leak Detection and Repair)
Worker exposure monitoring and industrial hygiene
Cleanroom monitoring and electronics component manufacturing
Headspace monitoring, soil contamination remediation, and detailed site analysis surveys
Aerospace, food & beverage, law enforcement, arson investigation, and fumigation
General personnel safety and industrial hygiene applications requiring wide-range ppm-level VOC measurement
| Minimum Detection Limit | 100 ppb |
| Detection Range | 0 - 4000 ppm (isobutylene equivalent) |
| T90 Response Time | < 3 seconds |
| Sensitivity | > 0.65 mV/ppm @ 100 ppm |
| Lamp Energy | 10.6 eV |
| Power & Signal | |
| Supply Voltage (internal regulator) | 3.6 – 18 V (non-intrinsically safe: 10 – 18 V) |
| Supply Voltage (regulated supply) | 3 – 3.6 V |
| Current | 20 – 32 mA (130 mA for 100 ms at start-up) |
| Power Consumption | 100 mW at 3.3 V |
| Output Signal (internal regulator) | 0 – 3.2 V |
| Output Signal (regulated supply) | 0 to rail voltage – 0.1 V |
| Environmental | |
| Temperature Range | -40 to 65 °C |
| Relative Humidity Range | 0 – 99% RH, non-condensing |
| Lifetime & Warranty | |
| Expected Life | > 5 years |
| Lamp Life | 10,000 hours (10.6 eV lamp) |
| Warranty | 12 months (10.6 eV lamp and MiniPID body; excludes electrode stack) |
Contact Person: Miss. Xu
Tel: 86+13352990255