logo
Home ProductsGas Sensor

ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors
ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

Large Image :  ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

Product Details:
Place of Origin: CN
Model Number: ZE03-CL2
Payment & Shipping Terms:
Minimum Order Quantity: 1PCS
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T
Supply Ability: 5000pcs

ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

Description
Measurement Range: 0- 20 Ppm Resolution: 0.1 Ppm
Response Time (T90): ≤ 60 S Working Voltage: DC 4- 9 V
Working Current: < 5 MA Operating Temperature: -20 °C To +50 °C
Highlight:

ZE03-CL2 chlorine gas sensor

,

electrochemical chlorine sensor module

,

portable water treatment chlorine detector

 

 

      ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

 

 

 

Key Features:

  • High sensitivity & resolution — 0.1 ppm resolution within the measurement range.

  • Dual output interface — UART (TTL, 3 V) and linear analog voltage output available concurrently.

  • Built-in temperature compensation — an on-board temperature sensor corrects readings across the operating temperature range, improving accuracy in variable environments.

  • Low power consumption — working current < 5 mA (typical), making the module suitable for battery-powered and portable instruments.

  • Good stability & anti-interference — the three-electrode electrochemical cell and circuit design provide repeatable performance and resistance to cross-interference.

  • Pre-calibrated & re-calibratable — factory calibration reduces integration effort; the module supports user recalibration where required.

  • Compact industrial package — designed for embedding into portable and fixed gas detectors.

 

 

Applications:

The ZE03-CL2 is deployed across chlorine-handling and chlorine-generation environments where continuous or spot monitoring of Cl2 is required:

 

 

 

  • Water and wastewater treatment — residual chlorine monitoring at water plants and chlorine dosing points in sewage treatment.

  • Chemical and industrial leak detection — fixed chlorine leak alarms in chemical plants and industrial facilities handling Cl2 gas.

  • Swimming pool and disinfection systems — chlorine level verification in pool water treatment and disinfection processes.

  • Portable chlorine detectors — handheld instruments for field screening and occupational safety checks.

  • Fixed gas detection equipment — integration into permanent gas-detection installations and multi-point monitoring systems.

  • General industrial toxic-gas monitoring — any application requiring ppm-level chlorine detection in ambient air.

Category Parameter Specification
Detection Target Gas Chlorine (Cl2)
  Measurement Range 0 -20 ppm (standard listing; some datasheet versions list 0 – 10 ppm)
  Resolution 0.1 ppm
  Response Time (T90) ≤ 60 s
Electrical Working Voltage DC 4 – 9 V (module input); DC 5 ± 0.1 V (official ZE03 series nominal)
  Working Current < 5 mA
  Output — Digital UART, TTL electrical level, 3 V (baud 9600, 8N1)
  Output — Analog Voltage output; 0.2 – 2.0 V cited for CL2 variant in some listings; 2 – 0 V cited in others (inverse scaling)
Environmental Operating Temperature −20 °C to +50 °C
  Operating Humidity 15 – 90 %RH, no condensation
  Storage Temperature −20 °C to +50 °C (some listings cite 20 – 25 °C for storage)
  Storage Humidity 15 – 90 %RH (some listings cite 30 – 70 %RH)
Mechanical & Life Dimensions ø23.5 mm × 24.5 mm (distributor listing); ø23.3 mm × 31.2 mm (official industrial-module drawing)
  Weight < 15 g (non-O2 ZE03 modules)
  Expected Working Life 2 years (in clean air)
  Certification RoHS compliant; anti-explosion and coal-mining safety certification cited for the platform

 

 

ZE03-CL2 Electrochemical Gas Sensor Module for Water and Wastewater Treatment Portable Chlorine Detectors

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255