Send Message
Home ProductsMedical Air Flow Sensor

HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM

I'm Online Chat Now

HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM

HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM
HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM

Large Image :  HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM

Product Details:
Place of Origin: USA
Brand Name: Honeywell
Model Number: HAFBLF0750CAAX5
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard Box
Delivery Time: 3-5Workingdays
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000pcs/Month

HAFBLF0750CAAX5 Digital Medical Air Flow Sensor 50 SCCM to 750 SCCM

Description
Type: Mass Air Flow Sensor Used For: Air
Range: 750 SCCM Accuracy: 2.5 %
Working Mode: Bidirectional Operating Supply Voltage: 4.5 V To 5.5 V
Highlight:

HAFBLF0750CAAX5 Medical Air Flow Sensor

,

Medical Air Flow Sensor 50 SCCM

,

Digital Air Flow Sensor 750 SCCM

HAFBLF0750CAAX5 Digital Airflow Sensors ±50 SCCM to ±750 SCCM

 

Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are
available at ±50, ±100, ±200, ±400 or ±750 SCCM. Custom flow ranges are also available. The sensors are fully calibrated
and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC).
The HAF Series is compensated over the temperature range of 0 °C to 50 °C [32 °F to 122 °F] and operates across a
temperature range of -20 °C to 70 °C [-4 °F to 158 °F]. The state-of-the-art ASIC-based compensation provides digital (I2
C) outputs with a response time of 1 ms

 

Specifications Sheet:

Port size Long Port
Shell Material Polymer
Maximum operating temperature + 70 C
Minimum operating temperature - 20 C
Output Type Analog
Series HAF
Unit weight 9.700 g
Supply voltage -0.3 Vdc to 6.0 Vdc
Voltage on I/O output pin -0.3 Vdc to Vsupply
Storage temperature range -40 °C to 125 °C [-40 °F to 257 °F]
Maximum flow change 5.0 SLPM/s
Maximum common mode pressure 25 psi at 25 °C [77 °F]
Maximum flow 10 SLPM

 