Product Details:
|
| Specification: | Each Piece Is 2 Meters Long | Outer Diameter: | 1.6mm |
|---|---|---|---|
| Inner Diameter: | 1.0mm; 10 Pieces Per Box Packaging | Material: | Medical-grade PUR Polyether Polyurethane |
| Temperature Range: | 0 - 50℃ | Sealing Performance: | NO |
| Negative Pressure Of Pump: | -20 To -80 Mbar | Adapting Connector: | Standard φ1.6 Raul |
| Highlight: | YJJ CO2 sample line hose,carbon dioxide sampling consumables,original CO2 sensor hose |
||
Product Description:
YJJ 8290286 Sample Line CO2 Sample Line Original Consumables - Carbon Dioxide Sampling Hose
Features:
I. Basic Parameters
Model: 8290286 (Original Delg CO2 Sampling Hose)
Specification: Single length 2m, outer diameter 1.6mm, inner diameter 1.0mm; 10 pieces per box packaging
Material: Medical-grade PUR polyether polyurethane, resistant to moisture, resistant to anesthesia corrosion, does not adsorb CO2 gas
Temperature range: 0 - 50℃, suitable for long-term stable use in ventilator internal environment
Air tightness: No leakage during low-pressure negative pressure sampling, compatible with the negative pressure (-20 to -80 mbar) of the built-in sampling pump in the equipment
Adapting connector: Standard φ1.6 Raul fine mouth, directly inserted into Delg mainstream monitoring / anesthesia machine CO2 module
II. Product Usage
1. Medical ventilator (main force)
Suitable for: Savina, Evita, Babylog8000 series Delg ventilators, peripheral flow CO2 monitoring sampling, extracting a small amount of exhaled gas from the airway / mask and sending it to the CO2 infrared sensor to measure end-expiratory carbon dioxide EtCO2.
2. Anesthesia machine accessories
Delg Fabius full series anesthesia machines, intraoperative anesthesia monitoring CO2 gas sampling pipeline.
3. Portable gas detector
Delg Oxylog series portable monitor, anesthesia gas detector external sampling pipeline.
4. Gas analyzer accessories
Medical gas monitoring instrument, exhaust gas analyzer short-distance gas guiding hose.
III. Product Features
Anti-condensation water, no pipe blockage, reducing water vapor entering the CO2 sensor and damaging the probe;
Low gas adsorption, CO2 measurement values without drift;
Reusability, aging and hardening, blockage requires replacement of 8290286.
Specifications:
| Adapting connector | Standard φ1.6 Raul |
| Pump negative pressure | -20 to -80 mbar |
| Sealing performance | No leakage during |
| Temperature range | 0 - 50℃ |
| Material | Medical-grade PUR polyether polyurethane |
| Inner diameter | 1.0mm; 10 pieces per box packaging |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255