Product Details:
|
| PM2.5 Effective Measuring Range: | 0~500μg/m³ | PM2.5 Maximum Measuring Range: | ≥1000μg/m³ |
|---|---|---|---|
| Mass Concentration Resolution: | 1μg/m³ | Sampling Volume: | 0.1L |
| Single Response Time: | <1S | Comprehensive Response Time: | ≤10S |
| Highlight: | compact digital laser particle sensor,high-precision particle sensor for air quality,embedded laser sensor for monitoring devices |
||
PMSA003 Compact, High-precision Digital Laser Particle Sensor for Embedded Integration in Various Miniaturized and Intelligent air Quality Monitoring Devices
|
Detectable Particle Size Range
|
0.3~1.0, 1.0~2.5, 2.5~10
|
μm
|
|
Particle Counting Efficiency
|
50%@0.3μm; 98%@≥0.5μm
|
-
|
|
PM2.5 Effective Measuring Range
|
0~500
|
μg/m³
|
|
PM2.5 Maximum Measuring Range
|
≥1000
|
μg/m³
|
|
Mass Concentration Resolution
|
1
|
μg/m³
|
|
Measurement Consistency (PM2.5)
|
±10μg/m³ (0~100μg/m³); ±10% (100~500μg/m³)
|
-
|
|
Sampling Volume
|
0.1
|
L
|
|
Single Response Time
|
<1
|
s
|
|
Comprehensive Response Time
|
≤10
|
s
|
|
Working Voltage
|
4.5~5.5 (Typical 5.0)
|
V
|
|
Working Current
|
≤80
|
mA
|
|
Standby Current
|
≤2
|
mA
|
|
Communication Level
|
Low<0.8V, High>2.7V (3.3V TTL)
|
V
|
|
Working Temperature
|
-10 ~ +60
|
℃
|
|
Working Humidity
|
0~95% (Non-condensing)
|
RH
|
|
Storage Temperature
|
-40 ~ +85
|
℃
|
|
MTBF (Mean Time Between Failures)
|
≥5
|
Years
|
|
Overall Dimension
|
48×37×12
|
mm
|
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255