logo
Home ProductsOther Sensors

PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

Certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
China ShenzhenYijiajie Electronic Co., Ltd. certification
I'm Online Chat Now

PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios
PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

Large Image :  PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

Product Details:
Place of Origin: CN
Model Number: PMS6003
Payment & Shipping Terms:
Minimum Order Quantity: 1PCS
Price: Negotiable
Packaging Details: Paper box
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS

PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

Description
Detectable Particle Size Range: 0.3~1.0, 1.0~2.5, 2.5~10μm PM2.5 Effective Measuring Range: 0~500μg/m³
PM2.5 Maximum Measuring Range: ≥1000μg/m³ Mass Concentration Resolution: 1μg/m³
Sampling Volume: 0.1L Single Response Time: <1s
Highlight:

PMS6003 digital laser particle sensor

,

long-life air quality sensor

,

high-standard continuous monitoring sensor

 

    PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios

 

 

Features:

  • Patented Dual-Laser Technology: Adopts exclusive dual-laser mutual calibration design, effectively reducing laser aging attenuation, doubling the overall service life and greatly improving long-term detection stability compared with traditional single-laser sensors.
  • Zero False Alarm Performance: Optimized optical path algorithm and structural design eliminate misjudgment caused by ambient light, tiny airflow and environmental interference, achieving stable zero false alarm operation in complex environments.
  • High-precision Tiny Particle Detection: Supports accurate identification of 0.3μm fine particles, with high counting efficiency and consistent detection data, meeting professional air quality monitoring accuracy requirements.
  • Upgraded Six-sided Shielding Structure: The new fully enclosed shielding structure effectively isolates external optical interference, electromagnetic interference and stray light influence, enhancing environmental adaptability.
  • Multi-parameter Synchronous Output: Simultaneously outputs PM1.0, PM2.5 and PM10 mass concentration data, covering full-range conventional air quality monitoring indicators.
  • Fast Intelligent Response: Supports real-time high-frequency data update for sudden concentration changes and stable average output in steady environment, balancing response speed and data accuracy.
  • Long Service Life & High Reliability: Professional aging resistance design, with ultra-long MTBF, suitable for long-term unattended continuous monitoring scenarios.
  • Standard Universal Interface: Equipped with TTL UART communication (9600bps, 8N1), compatible with mainstream MCUs, embedded systems and IoT modules, easy for secondary development and integration.

 

Applications:
  • High-end household and commercial air purifiers, intelligent fresh air systems and ventilation equipment
  • Professional indoor air quality monitors and high-precision environmental detection instruments
  • Smart building environmental monitoring systems and long-term indoor air quality management terminals
  • Public environment monitoring stations, community and commercial area air quality online monitoring devices
  • Industrial low-concentration dust monitoring and IoT long-term unattended environmental sensing nodes

 

Detection Principle
Laser Mie Scattering (Dual-laser Calibration)
-
Detectable Particle Size Range
0.3~1.0, 1.0~2.5, 2.5~10
μm
 
Particle Counting Efficiency
 
50%@0.3μm; 98%@≥0.5μm
-
PM2.5 Effective Measuring Range
0~500
μg/m³
PM2.5 Maximum Measuring Range
≥1000
 
μg/m³
Mass Concentration Resolution
1
μg/m³
Measurement Consistency (PM2.5)
±10μg/m³ (0~100μg/m³); ±10% (100~500μg/m³)
-
Sampling Volume
0.1
L
Single Response Time
<1
s
Comprehensive Response Time
≤10
s
Working Voltage
4.5~5.5 (Typical 5.0)
V
Average Working Current
≤120
mA
Standby Current
≤2
mA
Communication Level
3.3V TTL Level (Low<0.8V, High>2.7V)
V
Working Temperature
-10 ~ +60
Working Humidity
0~95% RH (Non-condensing)
-
Storage Temperature
-40 ~ +85
MTBF
≥6
Years
Overall Dimension
50 × 38 × 21
mm

 

PMS6003 High-end Long-life Digital Laser Particle Sensor For High-standard and Long-term Continuous air Quality Monitoring Scenarios 0

Contact Details
ShenzhenYijiajie Electronic Co., Ltd.

Contact Person: Miss. Xu

Tel: 86+13352990255

Send your inquiry directly to us (0 / 3000)