Product Details:
|
| Sensor: | Built-in NTC Thermistor | Measurement Range: | -30℃ ~ +70℃ |
|---|---|---|---|
| Measurement Accuracy: | ±0.5℃ (Full Range) | Resolution: | 0.1℃ |
| Size: | 60 × 38 × 18.5 Mm | Weight: | 35g |
| Protection Grade: | IP65 | Storage Capacity: | Maximum 16,000 Sets |
| Highlight: | Mini temperature humidity recorder,Industrial thermometer high-precision,Indoor temperature meter with warranty |
||
Product Description:
YJJ Testo 174T/174H Mini Temperature and Humidity Recorder Industrial Thermometer High-Precision Indoor Temperature Meter
Features:
I. Basic Product Information
Brand: Testo (a professional measuring instrument brand from Germany)
Full Name: testo 174T Single-Channel Mini Temperature Data Logger
Standard Order Number: 0572 1560 (Classic USB model), 0572 1740 (USB-C new model), 0572 1742 (Bluetooth BT version)
Position: Small one-time / Long-term continuous temperature automatic recording device, specifically for compliance cold chain certification
II. Core Hardware Parameters
1. Temperature Measurement Sensor Indicators
Sensor: Built-in NTC Thermistor
Measurement Range: -30℃ ~ +70℃
Measurement Accuracy: ±0.5℃ (Full Range)
Resolution: 0.1℃
Single-channel, only records temperature (174H series is a temperature-humidity dual-function model)
2. Storage and Recording Settings
Storage Capacity: Maximum 16,000 sets of temperature measurement data
Recording Interval: Free to set from 1 minute to 24 hours
Data Security: Automatic backup upon power failure / battery replacement, data not lost; supports password lock to prevent tampering
3. Physical and Protection
Size: 60 × 38 × 18.5 mm
Weight: 35g, compact and can be stuck / hung
Protection Grade: IP65, waterproof, splash-proof, dust-proof, no need to remove the recorder in case of cold storage water flushing
Shell: Resistant to low temperature hard engineering plastic
4. Power Supply and Battery Life
Battery: 2 CR2032 3V button batteries
Battery Life: In 25℃ environment, with a 15-minute recording cycle, it can last up to 500 days; minimum 24 months of ultra-long standby
Stable operation in low-temperature environments, no need to turn off the freezer
5. Communication Version Differentiation
Basic USB model (0572 1560)
Mini USB connected to a computer, using ComSoft software for reading, writing, and exporting reports
USB-C new model (0572 1740)
Type-C universal interface, compatible with modern computers
174T Bluetooth version (0572 1742)
Bluetooth wireless 30 meters, direct mobile phone reading, no need to plug in the computer for reporting
6. Compliance Certification
EN 12830 Cold Chain Transportation Logger Standard
HACCP Food Industry Compliance Certification (white model with NSF Food Contact Certification)
Industry can be equipped with ComSoft CFR software to meet 21 CFR Part11 data traceability regulations
III. Supporting Software Functions
ComSoft Basic (free): Recorder configuration, data reading, curve viewing, export of Excel/PDF/CSV reports
ComSoft Professional (paid): Multi-device batch management, custom alarm thresholds, batch reports
ComSoft CFR 21 Part11: GMP compliance for , audit tracking, electronic signature, non-modifiable data
Testo Smart App (Bluetooth version dedicated): Remote viewing on mobile phone, one-click generation of compliant reports
IV. Core Applications (Four Main Scenarios)
1. Food Cold Chain Industry (Core Application)
Refrigerated cabinets, freezer rooms, storage of fresh meat / dairy products in food processing plants, continuous monitoring of temperature in the cold storage area
Cold chain containers, refrigerated vehicles, full-process temperature traceability during food distribution
Compliance recording in raw material cold storage, semi-finished product cold storage of food processing plants, meeting HACCP inspections by food and supervision
Direct water washing of the recorder body for cold storage cleaning, IP65 does not require removal of the recorder
2. Medical / Biological Reagent Cold Chain
Low-temperature storage / transportation of vaccines, insulin, serum, biological samples throughout the process
The coolers in the hospital pharmacy and the reagent cold storage rooms automatically record data 24 hours a day. Combined with the CFR software, they meet GMP and 21CFR regulations.
Long-term monitoring of the -20/ -30℃ reagent boxes at low temperatures, with automatic marking of data in case of over-temperature.
3. HVAC (Heating, Ventilation, and Air Conditioning) and environmental monitoring for storage areas
Continuous collection of indoor temperatures in office buildings, computer rooms, and warehouses, including air conditioning system debugging and fault tracing.
Temperature monitoring of wine and chemical raw materials in constant temperature warehouses to prevent damage to goods due to temperature variations.
4. Industrial & Laboratory Low-Temperature Testing
Long-term collection of temperature curves for small-scale low-temperature test chambers and environmental chambers.
Simple data recording for aging of electronic components and materials under high and low temperatures.
Specifications:
| Detect the number of | Single gas detector |
| Measurement object | Single toxic gas |
| size | 118 mm x 60 mm x 30 mm |
| voltage | 180V |
| reaction time | 2S |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255