Product Details:
|
| Temperature Range: | -50°C To +400°C | Accuracy Class: | Class 2 (EN 60584-1) |
|---|---|---|---|
| Typical Error: | ±2.5°C | Response Speed: | T90 < 5s |
| Total Cable Length: | 1500 Mm | Probe Wire Diameter: | 1.5 Mm |
| Insulation Material: | High-temperature | Weight: | 30g |
| Highlight: | K type temperature sensor probe,high temperature HVAC sensor,flexible oven testing probe |
||
Product Description:
YJJ Testo 0602 0645 High Temperature Flexible K Type Temperature Sensor Probe for HVAC Oven Testing
Features:
I. Core Basic Specifications
Thermocouple Type: K-type (Nickel-Chromium/Nickel-Silicon NiCr-Ni), with standard K-type mini thermocouple plug
Temperature Range: -50°C to +400°C
Accuracy Class: Class 2 (EN 60584-1), typical error ±2.5°C
Response Speed: t90 < 5s, fast temperature response
Dimensions and Specifications
Total Cable Length: 1500 mm (1.5 meters)
Probe Wire Diameter: 1.5 mm
Insulation Material: High-temperature resistant fiberglass sheath, flexible and bendable cable
Weight: Approx. 30g
II. Product Features
High-Temperature Resistant Flexible Cable: Fiberglass insulation allows long-term use at up to 400°C; easily bent, threaded through narrow gaps, box openings, or door cracks for measurement
Ultra-Thin Probe: 1.5 mm ultra-fine tip ensures extremely fast air temperature response
Universal K-Type Connector: Compatible with most testo handheld thermometers, temperature-humidity data loggers, and anemometers (e.g., testo 108/922/925/440/175/176 series)
Lightweight design for convenient handheld inspection in the field
III. Typical Applications
Temperature monitoring of air ducts, ovens, aging chambers, and environmental chambers
Measuring temperatures in tight spaces such as HVAC ducts, ovens, and heat treatment equipment
Temperature measurement in confined industrial cavities, interlayers, door gaps, and narrow passages
Quick spot checks of process temperatures in laboratories and production lines
IV. Usage Limitations
Suitable only for air and gas temperature measurements; not recommended for direct immersion into liquids or highly corrosive media
Long-term operating temperature must not exceed 400°C continuously
Fiberglass sheath has moderate abrasion resistance; avoid contact with sharp or hard objects that may scratch the cable
V. Series Comparison Guide
Other models in the 0602 series include:
0602 0646: Extended version with 3-meter cable (all other specifications identical)
0602 0644: Shorter version with 0.5-meter cable
Specifications:
| Cable Insulation | Glass Fiber High |
| Total Length | 800mm |
| Wire Core Diameter | 1.5mm |
| Temperature measurement range | -50 ℃ ~ +400 ℃ |
| T90 response time | 5 seconds |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255