Product Details:
|
| Range: | +/- 1 L / Min | Port Size: | 5.08 Mm |
|---|---|---|---|
| For: | Dry Gas | Output Voltage: | 50 MV |
| Accuracy: | +/- 1% Reading | Product Type: | Flow Sensor |
| Highlight: | AWM2300V Flow Sensor,Industrial Liquid Flow Sensor,Min Range Flow Sensor |
||
AWM2300V Flow Sensor Microbridge Mass Airflow Unamplified Low Differential Pressure Sensing
The AWM2000 Series microbridge mass airflow sensor is a passive device comprised of two Wheatstone bridges. The heater control circuit in Figure 1 is required for operation per specifications.
The sensing bridge supply circuit in Figure 2 is also required for operation per specifications. These two circuits are not on board the package and must be supplied in the application. The differential amplifier in Figure 3 is a useful interface
for the sensing bridge. It can be used to introduce the gain and to introduce voltage offsets to the sensor output as referenced in Equation.
FEATURES
*Bidirectional sensing capability
*Actual mass air flow sensing
*Low differential pressure sensing
Specification:
| Flow Range (Full Scale) | ±1000 sccm |
| Output Voltage | 50 mV @ 650 sccm |
| Null Voltage Shift | ±0.20 mV |
| Output Voltage Shift | +5% Reading |
![]()
Contact Person: Xu
Tel: 86+13352990255