Product Details:
|
| Temperature Measurement Range: | -70 ℃ To +150 ℃ | Temperature Measurement Accuracy: | ±0.1℃ |
|---|---|---|---|
| Resolution: | 16-bit ADC ≈ 0.004 ℃ | Interface: | Standard I2C |
| Operating Voltage: | 1.8 V To 5.5 V | Compatible With: | 3.3V/5V |
| Standby: | 0.1 μA | Average: | 4.8 μA @ 1Hz |
| Highlight: | medical respiratory flow sensor,respiratory monitoring equipment,medical air flow sensor |
||
Product Description:
YJJ M1174442-S1 Respiratory Flow Sensor Medical Respiratory Monitoring Equipment
Features:
M1174442-S1 Respiratory Flow Sensor | Parameters + Applications
I. Basic Information
Model: M1174442-S1
Type: Reusable differential pressure type respiratory flow sensor (suitable for both newborns and adults)
Applicable equipment: GE 9100C Respiratory Machine (specific original accessory)
II. Core Technical Parameters
Measurement Principle: Differential pressure flow detection, generating pressure difference through respiratory airflow, accurately calculating tidal volume, flow rate, and flow velocity
Target Users: Newborns, infants, adults of all age groups for respiratory monitoring
Range: 0–180 L/min (bidirectional flow: inhalation + exhalation)
Accuracy: ±3% reading or ±0.15 L/min, high medical-grade precision
Material: Transparent medical-grade PC plastic, sterilizable at high temperature and pressure (134℃ high-pressure steam disinfection), reusable
Interface Specifications: Respiratory machine-specific quick-connect interface, compatible with GE 9100C gas path
Operating Temperature: 0~50℃; Tolerates sterilization temperature 134℃
Signal Output: Differential pressure analog signal, matching respiratory machine motherboard acquisition
Advantages: Anti-humidity interference, low air resistance, fast response, stable performance after disinfection
III. Main Applications
1. Core component of medical respiratory machines (primary purpose)
Compatible with GE 9100C respiratory machine, real-time monitoring of patient inhalation flow, exhalation flow, tidal volume, and respiratory rate
Used in intensive care, operating rooms, neonatology, ICU, emergency respiratory machines
Precisely feedback respiratory parameters, assisting respiratory machine in adjusting ventilation pressure, oxygen concentration, ensuring patient ventilation safety
2. Medical respiratory monitoring equipment
Anesthesia machine, pulmonary function instrument, non-invasive ventilator flow collection, precise measurement of respiratory airflow parameters
3. Medical equipment maintenance and replacement
Specifications:
| Range | 0–180 L/min |
| Operating Temperature | 0~50℃ |
| Tolerates sterilization temperature | 134℃ |
| Power supply | 5 VDC ±1% |
| Operating temperature | -10 ℃ ~ +70 ℃ |
| Storage temperature | -20 ℃ ~ +80 ℃ |
![]()
Contact Person: Miss. Xu