Product Details:
|
| Operating Pressure: | 0 - 80 CmH₂O | Adapted Tidal Volume: | 2 - 200 Ml |
|---|---|---|---|
| Operating Temperature: | +10℃ ~ +40℃ | Measurement Accuracy: | ≤ ±3% FS |
| Storage Environment: | -10℃ ~ +50℃ | Response Speed: | Quickly Captures Weak Airflows |
| Highlight: | Disposable neonatal SPU flow sensor,SLE2000 ventilator flow sensor,SLE5000 medical air flow sensor |
||
Product Description:
YJJ 151110 Disposable Neonatal SPU Flow Sensor for SLE2000 SLE5000 Ventilato
Features:
Basic Introduction
Original model: 151110 (SPU Flow Sensor Assembly)
Compatible equipment: SLE2000, SLE5000 Newborn Respiratory Ventilators
Product Attributes: One-time disposable medical differential pressure respiratory flow sensor, specifically designed for measuring low tidal volume ventilation in premature and newborn infants, avoiding cross-infection
Core Technical Parameters
Measurement principle: Differential pressure airflow sensing
Ventilation range: 0 - 180 L/min, bidirectional inhalation and exhalation flow detection
Adapted tidal volume: 2 - 200 ml (newborn / premature infant low tidal volume)
Measurement accuracy: ≤ ±3% FS
Response speed: Quickly captures weak airflow, compatible with high-frequency oscillatory ventilation
Operating pressure: Normal neonatal ventilator airway pressure range 0 - 80 cmH₂O
Ventilation resistance: Low pressure loss, does not increase the respiratory load of the child
Material and physical specifications
Contact airflow material: Medical-grade sterile plastic, disposable
Interface specification: SLE ventilator-specific quick-insert connector
Packaging: Independent sterile packaging, single unit independent sterilization
Usage attributes: Single use, not reusable for disinfection and reuse, eliminates cross-infection in hospitals
Environmental conditions
Operating temperature: +10℃ ~ +40℃
Storage environment: -10℃ ~ +50℃, dry and protected from light storage
Compatible models & application scenarios
Compatible ventilators
SLE-2000, SLE-5000 Infant-specific Ventilators
Usage scenarios
Newborn ICU, obstetric delivery room, premature infant nursery, maternal and child health hospital, pediatric intensive care unit, neonatal non-invasive / invasive ventilation, high-frequency oscillatory ventilation equipment consumables and accessories
Product features
High sensitivity, accurately identifies weak respiratory airflow of newborns
One-time sterile structure, eliminates disinfection procedures, prevents patient cross-infection
Low pressure loss, does not interfere with the ventilator parameters of the child
Plug-and-play, easy to disassemble and assemble, stable flow calibration of the ventilator
Specifications:
| Ventilation range | 0 - 180 L/min |
| Adapted tidal volume | 2 - 200 ml |
| Measurement accuracy | ≤ ±3% FS |
| Operating temperature | +10℃ ~ +40℃ |
| Storage environment | -10℃ ~ +50℃ |
![]()