Product Details:
|
| Flow Range: | 0.5 - 50 SLPM | Measurement Accuracy: | ±(1.5 + 0.2% FS) |
|---|---|---|---|
| Repeatability: | ≤ ±0.5% FS | Range Ratio: | 100:1 |
| T90 Response Time: | 125ms | Calibration Reference: | 20℃ |
| Power Supply Voltage: | DC12 - 24V | Working Current: | ≤ 50mA |
Product Description:
YJJ MF5006-N-E-0.5-50-06-D-N 0.5-50SLPM Digital Gas Mass Flowmeter RS485 Modbus Thermal Flow Sensor
Features:
I. Disassembly of Model MF5006-N-E-0.5-50-06-N-D-N-N
MF5006: MF5000 series, DN6 specification flowmeter
N: Standard version
E: With LCD display + physical buttons
0.5-50: Measurement range 0.5-50 SLPM (standard liters per minute)
06: Pipe interface NPT1/4-INCH external thread
D: Output: 4-20mA analog + RS485-Modbus communication
N: No special customization options
II. Complete technical parameters Table
Parameter Item Specification Details
Sensing Principle MEMS thermal micro-electromechanical sensing
Measurement Medium Nitrogen, air, oxygen, argon, etc. dry and non-corrosive gases
Measurement Accuracy ±(1.5% FS + 0.5% reading)
Response Time ≤ 125ms
Power Supply Voltage DC12-24V, maximum working current 20mA
Signal Output 4-20mA, RS485 Modbus-RTU, pulse output
Mechanical Interface NPT1/4 external thread
Maximum Pressure 1.5MPa
Environmental Temperature -20℃~+60℃
Medium Temperature -10℃~+55℃
Shell Material Aluminum alloy, flow channel stainless steel
Protection Grade IP40
Specifications:
| Model Number | MF5006-N-E-0.5-50-06-D-N |
| Usage | Module |
| Condition | Original 100% |
| precision | ± (2.5+ 0.5FS)% |
| Power supply | 18 - 28V DC |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255