Product Details:
|
| Full Scale: | 500 ML/min | Accuracy: | ±3% F.S. |
|---|---|---|---|
| Repeatability: | 0.5% F.S. | Response Time: | ≤2 S |
| Highlight: | AMC2100R02 mass flow controller,500 mL/min flow controller,medical air flow sensor |
||
AMC2100R02 Mass Flow Controller MFC Measurement Range 500 mL/min
- Applications: Precise gas flow control; commonly used in laboratory equipment, welding, gas mixing, and low-flow gas supply for semiconductor applications.
- Communication: DB9 interface, Modbus-RTU; also supports 0–5V analog setpoint/feedback.
Specification:
| Power supply | 24 V DC |
| Output | RS485 (Modbus-RTU) / 0–5 V |
| Analog voltage interface | DB9 male connector |
| Operating pressure | 0.15–0.35 MPa |
| Power consumption | ≤3 W |
| Calibration reference | Air at standard conditions; suitable for gases such as N₂ and O₂ (requires gas conversion factors) |
![]()
Contact Person: Xu
Tel: 86+13352990255