| Principle: | Thermal Mass Flow | Range: | 0- ±200 Sccm |
|---|---|---|---|
| Accuracy: | ±3% Of Reading | Repeatability: | ±1% Of Reading |
| Sampling Period: | 0.5 S | Power Supply: | 4.75 To 5.25 V DC |
| Working Current: | 7.5 To 10 MA | Working Temperature: | -25 ℃ To +85 ℃ |
| Highlight: | AFS01 thermal mass flow sensor,I2C micro flow sensor ±200sccm,medical air flow sensor ventilator |
||
Product Description:
YJJ AFS01 Thermal Mass Micro Flow Sensor 0-±200sccm I2C for Ventilator and Laboratory Gas Mixing
Features:
Product Introduction: AFS01 Thermal Gas Microflow Sensor, based on the principle of heat transfer, features a built-in 24-bit ADC + MCU. It is **fully calibrated at factory** and supports bidirectional gas mass flow measurement. It has an I2C digital output and is used for detecting small flow rates of non-corrosive gases. Guangzhou Aosong Electric...
Core Technical Parameters
| Measurement Principle | Thermal Flow Sensing (Principle of Heat Transfer) |
| Flow Range | **0~±200 sccm (Standard Condition, Bidirectional Measurement)** |
| Measurement Accuracy | ±3% Reading (Standard Air) |
| Repeatability | ±1% Reading |
| Sampling Period | 0.5s (500ms) |
| Supply Voltage | **4.75~5.25VDC (Typical 5V)** |
| Working Current | 7.5~10mA, Power Consumption < 50mW |
| Communication Interface | I²C, Rate 100~400KHz |
| Working Temperature | -25℃ ~ +85℃ |
| Storage Temperature | -25℃ ~ +90℃ |
| Applicable Medium | Air and Various **Non-Corrosive Dry Gases** |
| Measurement Characteristics | Can Identify Flow Direction, Small Lag Error |
| Calibration | Factory Calibration, Direct Output of Flow Value, No Secondary Calibration Required |
Product features
1. Bidirectional micro-flow detection, capable of identifying gas flow direction
2. Built-in 24-bit ADC + MCU, I2C digital output, facilitating connection with microcontrollers and PLCs
3. Factory complete calibration, ready to use upon receipt, reducing development costs
4. Low power consumption, compact size, direct plug-in installation for pipelines
5. Strong anti-interference ability, good long-term stability, suitable for batch OEM integration
Typical application scenarios
Medical equipment, gas analysis instruments, leak detection equipment, respiratory equipment, laboratory gas lines, gas quality monitoring, industrial micro-gas flow control
Specifications:
| Power supply | 4.75 - 5.25 V DC |
| Operating current | 7.5 - 10 mA |
| Output interface | I²C |
| Maximum frequency | 400 kHz |
| Operating temperature | -25 ℃ ~ +85 ℃ |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255