Product Details:
|
Maximum Overload Pressure: | 800 KPa | Typical Sensitivity: | 0.2 MV/kPa |
---|---|---|---|
Installation Type: | Through-hole | Package Type: | Boxed (344C-01) |
Number Of Pins: | 4PIN | Size: | 29.85 X 11.05 X 29.34 Mm |
Highlight: | dual-tube pressure sensor industrial,temperature-compensated pressure sensor medical,electronic differential pressure sensor |
Product Description:
YJJ MPX2200DP Dual-Tube Differential Pressure Temperature-Compensated Pressure Sensor Is Applied In Industrial And Medical Fields
Features:
MPX2200DP pressure sensor is mainly used for measuring the pressure of gases or liquids. Its measurement range is 0 to 200 kPa and the accuracy is 1%. It is suitable for industrial automation, environmental monitoring and other fields.
Specific application scenarios:
Industrial Automation: Used for pressure monitoring in industrial equipment, such as pressure detection in gas/liquid pipelines, to ensure that the system operating pressure meets the requirements.
Environmental Monitoring: Can be applied in scenarios such as air quality monitoring and temperature/humidity control, for example, measuring the impact of environmental pressure changes on equipment operation.
Automotive Electronics: Some models may use such sensors for pressure detection, but the specific application is not explicitly mentioned in the search results.
For more detailed information, it is recommended to directly contact the product supplier or refer to the official technical documentation.
Pressure sensor transmitter MPX2200AP
MAXIMUM RATINGS
Rating Symbol Value Unit
Overpressure(8) (P1 > P2) Pmax 0-200 kPa
Burst Pressure(8) (P1 > P2) Pburst 2000 kPa
Storage Temperature Tstg –40 to +125 °C
Operating Temperature TA –40 to +125 °C
OPERATING CHARACTERISTICS (VS = 10 Vdc, TA = 25°C unless otherwise noted, P1 > P2)
Characteristics Symbol Min Typ Max Unit
Pressure Range(1) POP 0 — 200 kPa
Supply Voltage VS — 10 16 Vdc
Supply Current Io — 6.0 — mAdc
Full Scale Span(3) VFSS 38.5 40 41.5 mV
Offset(4) Voff –1.0 — 1.0 mV
Sensitivity DV/DP — 0.2 — mV/kPa
Specifications:
General packaging | SIP-4 |
RoHS | Compliance |
Installation method | Through-hole installation |
Working temperature | -40℃ to 125℃ |
Contact Person: Miss. Xu
Tel: 86+13352990255