Product Details:
|
| Measurement Range: | 0 - 10 Bar G (gauge Pressure / 0 - 1000 KPa) | Overall Accuracy: | ±0.25% FS |
|---|---|---|---|
| Total Error Band: | TEB ±1.0% FS | Overload Pressure: | 20 Bar |
| Explosion Pressure: | 50 Bar | Response Time: | < 3 Ms |
| Zero Point Drift: | ≤ ±0.1% FS Per Year | Output: | 4 - 20 MA Two-wire System |
| Highlight: | Industrial pressure transmitter for HVAC,0-10Bar refrigeration pressure sensor,Electronic pressure sensor with warranty |
||
Product Description:
YJJ M5256-C3079E-010BG 0-10Bar Industrial Pressure Transmitter for HAVC Refrigeration
Features:
M5256: M5200 Compact Micro-forged Stainless Steel Pressure Transmitter Platform
C3079E: Electrical + Threaded Combined Code
Digital 3: Output Signal = 4-20mA Two-wire Current Output
079: Electrical Connector = DIN43650 Type A Right-angle Hirschmann Plug
E: Process Thread = PT1/4 (R1/4) British Metric Conical Pipe External Thread
010: Range 0-10 Bar G (Gauge Pressure, 0-1 MPa)
B: Pressure Type = Gauge Pressure (One side connected to the atmosphere measures relative pressure)
G: Standard Circuit Protection Configuration (Reverse Connection, Short Circuit, EMI Surge Protection)
II. Core Technical Performance Parameters
1. Pressure Performance Table
Parameters and Specifications
Measurement Range: 0 - 10 Bar G (gauge pressure / 0 - 1000 kPa)
Overall Accuracy (non-linearity + hysteresis + repeatability): ±0.25% FS
Total Error Band (TEB): ±1.0% FS over the entire temperature range
Safety Overload Pressure: 2 times the rated range (20 Bar)
Explosion-proof Breaking Pressure: 5 times the rated range (50 Bar)
Response Time: < 3ms, no lag in dynamic pressure
Annual Long-Term Zero Drift: ≤ ±0.1% FS per year
2. Electrical Specifications
Output: 4 - 20mA two-wire system (0 Bar = 4mA, 10 Bar = 20mA)
Power Supply Voltage: 9 - 30VDC (common for industrial standard 24VDC systems)
Load Upper Limit: Maximum 500Ω
Circuit Protection: Reverse power connection protection, output short circuit protection, 10V/m electromagnetic surge EMC protection
Insulation Strength: 100MΩ @ 500VDC
Connection: 3-core right-angle Hirschmann DIN43650 plug, easy to plug and unplug, resistant to vibration
3. Mechanical and Medium Compatibility
Contact Material: 17-4PH stainless steel integrated micro-fusion core body, no welds, no rubber sealing ring, less prone to leakage, resistant to oil and water
Process Interface: PT1/4 (R1/4) external conical thread, combined with Teflon gasket seal
Protection Grade: IP67, suitable for outdoor and humid cabinets
Anti-Vibration: 20G (20 - 2000Hz); Impact Resistance: 50G
Overall Size: Cylindrical compact type, six-sided edge 24mm, total length 50mm, easy installation in limited equipment space
Weight: Approximately 85g
4. Temperature Parameters
Medium Working Temperature: -40℃ ~ +125℃
Factory Temperature Compensation Range: -20℃ ~ +85℃ (full temperature range calibration, no significant drift in high and low temperatures)
Storage Temperature: -40℃ ~ +125℃
Applicable Media: Compressed air, hydraulic oil, clean water, low-pressure steam, mild weakly corrosive fluids
5. Certifications
CE Industrial Electromagnetic Compatibility Certification, RoHS Environmental Compliance
3. Core Product Advantages
Integrated Stainless Steel Core Body: No O-ring sealing structure, resistant to oil, water vapor, high and low temperatures, with a lifespan far exceeding ordinary diffusion silicon transmitters;
Wide Voltage 9 - 30VDC power supply, compatible with machine tools, air compressors, PLC control cabinets with 24V DC power supply;
Built-in multiple circuit protections, no damage to the sensor due to incorrect wiring or short circuits during on-site connection, high debugging fault tolerance rate;
IP67 waterproof right-angle Hirschmann connector, less likely to loosen or break in vibration environments;
Factory full temperature range calibration, highly interchangeable, no need to re-calibrate the system upon replacement.
4. Main Application Scenarios
1. Hydraulic/Air Automation Equipment (Most Commonly Used)
Injection molding machines, die-casting machine servo hydraulic system oil pressure closed-loop monitoring;
Air compressors, vacuum pumps, storage tank pressure stabilization, high and low pressure start-stop control;
Pressing fixtures, automated assembly lines oil pressure collection, overpressure alarm.
2. HVAC, Refrigeration and Water Treatment
Water pressure transmitters for chilled water / hot water pipes in central air conditioning;
Pressure monitoring for drying machines, air compressors;
Constant pressure control for water purification equipment, circulating water pipelines, water shortage interlock protection.
3. General Industrial Equipment
Low-pressure pressure detection for small steam boilers, heat treatment equipment;
Pressure feedback for laser cutting, printing, packaging equipment;
Data collection for pressure testing fixtures, aging test benches.
Specifications:
| Load limit | Maximum 500Ω |
| Power supply voltage | 9 - 30VDC |
| Output | 4 - 20 mA two-wire |
| Zero point drift | ≤ ±0.1% FS per year |
| Response time | < 3 ms |
| Explosion pressure | 50 Bar |
![]()
Contact Person: Miss. Xu
Tel: 86+13352990255